Download Data Sheet
CONSTRUCTION & DIMENSIONS
CONDUCTOR PARAMETER
• Number of Conductors
2
• AWG Size
20
• Conductor Stranding
7x28
• Conductor Type
Bare copper
• Nominal DCR
10.5 Ohm/1000ft
• Cabling Lay Length
2.5 in
• Twists/Foot
4.8 twist/ft
INSULATION PARAMETER
• Insulation Type
Plenum PVC
• Insulation Thickness
0.007 in
• Insulation Color Code
1. Black 2.Red
SHIELDING PARAMETER
• Shield Type
Overall 100% Aluminum Foil
• Drain Wire Type
Tinned Copper
• Drain Wire AWG
24 AWG
ELECTRICAL CHARACTERISTICS
• Nom. Cap. Between Conductors
60 pF/ft
• Nom. Cap. Conductor to Shield
108 pF/ft
OVERALL CONSTRUCTION PARAMETERS
Jacket Type
Flexible Plenum
Jacket Thickness
0.015 in
Nominal Cable O.D.
0.138 in
Plenum
Yes
NEC UL Rating
CMP
RoHS Compliant
Pull Tension
39 lbs
Bend Radius
1.242 in
Cable Weight
15 lbs
OVERALL ELECTRICAL/OPTICAL CHARACTERISTICS
UL Flammability
NFPA 262 Plenum
Operating Range
-0 to 60 Deg C
UL Voltage Rating
300