Download Data Sheet
CONSTRUCTION & DIMENSIONS
-
CONDUCTOR PARAMETER
• Number of Conductors
2
• AWG Size
16
• Conductor Stranding
19x29
• Conductor Type
Bare copper
• Nominal DCR
4.2 Ohm/1000ft
• Cabling Lay Length
3 in
• Twists/Foot
4 twist/ft
INSULATION PARAMETER
• Insulation Type
Plenum PVC
• Insulation Thickness
0.008 in
• Insulation Color Code
1. Black 2.Red
SHIELDING PARAMETER
• Shield Type
Overall 100% Aluminum Foil
• Drain Wire Type
Tinned Copper
• Drain Wire AWG
24 AWG
ELECTRICAL CHARACTERISTICS
• Nom. Cap. Between Conductors
75 pF/ft
• Nom. Cap. Conductor to Shield
140 pF/ft
OVERALL CONSTRUCTION PARAMETERS
Jacket Type
Flexible Plenum
Jacket Thickness
0.015 in
Nominal Cable O.D.
0.178 in
Plenum
Yes
NEC UL Rating
CMP
RoHS Compliant
Pull Tension
69 lbs
Bend Radius
1.60 in
Cable Weight
30 lbs
BELDEN: 6200FE
OVERALL ELECTRICAL/OPTICAL CHARACTERISTICS
UL Flammability
NFPA 262 Plenum
Operating Range
-0 to 60 Deg C
UL Voltage Rating
300
RELATED PRODUCTS