JavaScript is currently disabled on your mobile device. Please enable JavaScript and reload the page.
Download Data Sheet
CONSTRUCTION & DIMENSIONS
-
CONDUCTOR PARAMETER
• Number of Conductors
1
• AWG Size
14
• Conductor Stranding
Solid
• Conductor Type
Copper Covered Steel -CCS
• Nominal DCR
11 Ohm/1000ft
INSULATION PARAMETER
• Insulation Type
Foam Polyethylene
• Insulation Thickness
0.28 in
SHIELDING PARAMETER
• Shield Type
Overall 100% Aluminum Foil
• Shield Type 2
Aluminum Braid
ELECTRICAL CHARACTERISTICS
• Nominal Impedance
75 Ohm
• Nom. Cap. Between Conductors
16.2 pF/ft
OVERALL CONSTRUCTION PARAMETERS
Jacket Type
PVC
Jacket Thickness
0.044 in
Nominal Cable O.D.
0.405 in
Plenum
No
NEC UL Rating
CATV-CM
Pull Tension
150 lbs
Bend Radius
3.645 in
Cable Weight
73 lbs
BELDEN: 1523A
OVERALL ELECTRICAL/OPTICAL CHARACTERISTICS
Nominal Velocity of Propagation (VP)
82 %
UL Flammability
UL1685
Operating Range
-20 to 60 Deg C
UL Voltage Rating
300
FREQUENCY (MHz)
ATTENUATION (db/100ft)
5 MHz
0.38 dB
55 MHz
0.92 db dB
100 MHz
1.2 dB
270 MHz
1.92 dB
400 MHz
2.4 dB
540 MHz
2.85 dB
750 MHz
3.4 dB
1000 MHz
4.05 dB
1450 MHz
5.05 dB
2250 MHz
6.42 dB
3000 MHz
7.46 dB
RELATED PRODUCTS
Plenum Number
25821
“F” Type Crimp
CN-F11ALX
“F” Type Compression
CN-FS11V
Thank you, .
You will be notified via SMS at () and via e-mail () when will be notified by e-mail () when will be notified via SMS at () when is available.
Youwill be notified via SMS at () when will be notified by e-mail () when is available.
Your message has been sent to ()