JavaScript is currently disabled on your mobile device. Please enable JavaScript and reload the page.
Download Data Sheet
CONSTRUCTION & DIMENSIONS
-
CONDUCTOR PARAMETER
• Number of Conductors
1
• AWG Size
25
• Conductor Stranding
Solid
• Conductor Type
Bare Copper
• Nominal DCR
30 Ohm/1000ft
INSULATION PARAMETER
• Insulation Type
Foam Polyethylene
• Insulation Thickness
0.085 in
SHIELDING PARAMETER
• Shield Type
95% Bare Copper Braid
ELECTRICAL CHARACTERISTICS
• Nominal Impedance
75 Ohm
• Nom. Cap. Between Conductors
16.2 pF/ft
OVERALL CONSTRUCTION PARAMETERS
Jacket Type
PVC
Jacket Thickness
0.02 in
Nominal Cable O.D.
0.146 in
Plenum
No
NEC UL Rating
CM
RoHS Compliant
Yes
Pull Tension
25 lbs
Bend Radius
1.46 in
Cable Weight
16 lbs
OVERALL ELECTRICAL/OPTICAL CHARACTERISTICS
Nominal Velocity of Propagation (VP)
82 %
UL Flammability
UL1685
Operating Range
-20 to 60 Deg C
UL Voltage Rating
300
FREQUENCY (MHz)
ATTENUATION (db/100ft)
1 MHz
0.5 dB
10 MHz
1.8 dB
50 MHz
3.12 dB
100 MHz
4.19 dB
200 MHz
5.79 dB
400 MHz
8.59 dB
700 MHz
11.14 dB
900 MHz
13.22 dB
1000 MHz
14.41 dB
RELATED PRODUCTS
Plenum Number
25825
BNC Crimp
CN-BM74-18
BNC Compression
CN-BNCP-825
RCA Compression
CN-RCP-825
Thank you, .
You will be notified via SMS at () and via e-mail () when will be notified by e-mail () when will be notified via SMS at () when is available.
Youwill be notified via SMS at () when will be notified by e-mail () when is available.
Your message has been sent to ()