Download Data Sheet
CONSTRUCTION & DIMENSIONS
|
-
|
CONDUCTOR PARAMETER
|
-
|
• Number of Pairs
|
2
|
• AWG Size
|
22
|
• Conductor Stranding
|
7x30
|
• Conductor Type
|
Tinned Copper
|
• Nominal DCR
|
17 Ohm/1000ft
|
INSULATION PARAMETER
|
-
|
• Insulation Type
|
FEP
|
• Insulation Thickness
|
0.007 in
|
• Insulation Color Code
|
1. Black 2.Red
|
SHIELDING PARAMETER
|
-
|
• Shield Type
|
Individually Shielded each has a drain wire
|
• Drain Wire Type
|
Tinned Copper (2 drain wire each Ind. Shield)
|
• Drain Wire AWG
|
24 AWG
|
ELECTRICAL CHARACTERISTICS
|
-
|
• Nominal Impedance
|
55 Ohm
|
• Nom. Cap. Between Conductors
|
35 pF/ft
|
• Nom. Cap. Conductor to Shield
|
67 pF/ft
|
OVERALL CONSTRUCTION PARAMETERS
|
-
|
Total Number of Conductors
|
4
|
Jacket Type
|
Flexible Plenum
|
Jacket Thickness
|
0.017 in
|
Nominal Cable O.D.
|
0.218 in
|
Plenum
|
Yes
|
NEC UL Rating
|
CMP
|
RoHS Compliant
|
Yes
|
Pull Tension
|
55 lbs
|
Bend Radius
|
1.962 in
|
Cable Weight
|
27 lbs
|
Belden: 6541PA - Note 6541PA has a PVDF Jacket for indoor/outdoor use.