JavaScript is currently disabled on your mobile device. Please enable JavaScript and reload the page.
Download Data Sheet
CONDUCTOR PARAMETER
-
• Number of Conductors
1
• AWG Size
14
• Conductor Stranding
Solid
• Conductor Type
Bare copper
• Nominal DCR
2.6 Ohm/1000ft
INSULATION PARAMETER
• Insulation Type
Foam Polyethylene
• Insulation Thickness
0.28 in
SHIELDING PARAMETER
• Shield Type
Overall 100% Aluminum Foil + Aluminum Braid 65%
• Shield Type 2
Overall 100% Aluminum Foil + Aluminum Braid 55%
• Nom. DCR Shield
2.6 Ohms/1000ft
ELECTRICAL CHARACTERISTICS
• Nominal Impedance
75 Ohm
• Nom. Cap. Between Conductors
16.2 pF/ft
OVERALL CONSTRUCTION PARAMETERS
Jacket Type
Polyethylene
Nominal Cable O.D.
0.405 in
Plenum
No
NEC UL Rating
CATV
RoHS Compliant
Yes
Bend Radius
4.05 in
Cable Weight
60 lbs
Max. Pull Tension
315 lbs
OVERALL ELECTRICAL/OPTICAL CHARACTERISTICS
Nominal Velocity of Propagation (VP)
82 %
UL Flammability
Article 725
Operating Range
-25 to 60 Deg C
UL Voltage Rating
300
Frequency (MHz)
Attenuation (db/100ft)
5 MHz
0.38 db/100/ft
55 MHz
0.92 db/100/ft
100 MHz
1.2 db/100/ft
270 MHz
1.92 db/100/ft
400 MHz
2.4 db/100ft
540 MHz
2.85 db/100ft
750 MHz
3.9 db/100ft
1000 MHz
4.05 db/100ft
1450 MHz
5.05 db/100ft
2250 MHz
6.79 db/100ft
3000 MHz
7.58 db/100ft
RELATED PRODUCTS
Plenum Number
25Q821
“F” Type Crimp
CN-F11ALX
“F” Type Compression
CN-FS11V
Thank you, .
You will be notified via SMS at () and via e-mail () when will be notified by e-mail () when will be notified via SMS at () when is available.
Youwill be notified via SMS at () when will be notified by e-mail () when is available.
Your message has been sent to ()