Download Data Sheet
CONSTRUCTION & DIMENSIONS
-
Component
Shielded
Unshielded
CONDUCTOR PARAMETER
• Number of Conductors
2
4
• AWG Size
22
• Conductor Stranding
Solid
• Conductor Type
Bare Copper
• Nominal DCR
17 Ohm/1000ft
INSULATION PARAMETER
• Insulation Type
PVC
• Insulation Thickness
0.01 in
• Insulation Color Code
1. Black 2.Red
1. White 2.Green 3.Brown 4.Blue
SHIELDING PARAMETER
• Shield Type
Overall 100% Aluminum Foil
None
• Shield Type 2
Aquaseal Water Blocking Tape
• Drain Wire Type
Tinned Copper
• Drain Wire AWG
22 AWG
ELECTRICAL CHARACTERISTICS
• Nom. Cap. Between Conductors
54 pF/ft
• Nom. Cap. Conductor to Shield
97 pF/ft
OVERALL CONSTRUCTION PARAMETERS
Total Number of Conductors
6
Jacket Type
UV Resistant PVC
Jacket Thickness
0.025 in
Nominal Cable O.D.
0.24 in
Plenum
No
NEC UL Rating
CM, CL3
RoHS Compliant
Yes
TIA Test
TIA455-82 Water Penetration Test
Pull Tension
69 lbs
Bend Radius
2.16 in
Cable Weight
29 lbs
OVERALL ELECTRICAL/OPTICAL CHARACTERISTICS
UL Flammability
UL1685
Operating Range
-20 to 60 Deg C
UL Voltage Rating
300